If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
75W Single Output Switching Power Supply Features : Universal AC input / Full range LPS-75 series Protections: Short circuit / Overload / Over voltage Cooling by free air convection PWM control and regulated Small and compact size Built-in remote ON-OFF control LED indicator for power on 100% full load burn-in test 2 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD(10sec.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE FUNCTION REMOTE ON/OFF WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 5) LPS-75-3.3 3.3V 15A 0 ~ 16.5A 49.5W Note.4 54.45W LPS-75-5 5V 15A 0 ~ 16.5A 75W 82.5W 80mVp-p 4.75 ~ 5.5V 3.0% 1.0% 3.0% LPS-75-12 12V 6.2A 0 ~ 6.8A 74.4W 81.6W 100mVp-p 11 ~ 13.5V 2.0% 1.0% 2.0% LPS-75-15 15V 5A 0 ~ 5.5A 75W 82.5W 100mVp-p 13.5 ~ 16.5V 2.0% 1.0% 2.0% LPS-75-24 24V 3.2A 0 ~ 3.5A 76.8W 84W 120mVp-p 22 ~ 27V 2.0% 1.0% 1.0% LPS-75-48 48V 1.56A 0 ~ 1.7A 75W 81.6W 120mVp-p 45 ~ 54V 2.0% 1.0% 1.0% RIPPLE & NOISE (max.) Note.2 80mVp-p 3 ~3.5V 3.0% 1.0% 3.0% 100ms, 35ms/230VAC 60ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 69% 77% 100ms, 35ms/115VAC at full load 12ms/115VAC at full load 127 ~ 370VDC 80% 81% 83% 83% 1.9A/115VAC 1.1A/230VAC COLD START 18A/115VAC 36A/230VAC <1mA / 240VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 27.6 ~ 32.4V 57.6 ~ 67.2V ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF DIMENSION PACKING Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 355Khrs min. MIL-HDBK-217F (25 ) 222*55*30mm (L*W*H) 0.3Kg; 48pcs/15.6Kg/1.12CUFT OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:LPS-75-SPEC 2008-03-25 75W Single Output Switching Power Supply Mechanical Specification 222 212 LPS-75 series Unit:mm CN1 5 1 CN3 2 1 2 CN2 3 4 5 6 LED 55 45 3 1 SVR1 4- 3.8 AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment AC/L No Pin AC/N FG Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 2 max. 30 DC Output Connector (CN2) : JST B6P-VH or equivalent Pin No. 1,2,3 4,5,6 Assignment -V +V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent Pin No. 1 2 Assignment RC+ RCMating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent Block Diagram RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER fosc : 60KHz EMI FILTER +V -V I/P FG O.L.P. PWM CONTROL DETECTION CIRCUIT Derating Curve Static Characteristics (15V) Ta=25 100 21 300 250 200 150 100 50 25 1 80 18 3 1 Convection 2 18CFM Forced Air 3 5V Only 15 12 9 6 3 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPS-75-SPEC 2008-03-25 OUTPUT RIPPLE (mVp-p) 2 OUTPUT VOLTAGE (V) LOAD (%) |
Price & Availability of LPS-75-24 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |